Howto calculate the diameter of the tubing in sanitary installations

This little online script use the french plumbing code. It's the DTU 60.11 which is used. The pressure of water is considered at 43.5 psi (3 bars). The frenchies use "pressure reducers" to get this pressure level.


Fixture Number - cold water Number - hot water Coefficient
Toilet (with flush), washbasin (hand), urinal, floor trap - 0,5
Bidet, clothes washer, dish washer 1
Sink (bathroom) 1,5
Shower 2
Sink (kitchen) 2,5
Bathtub 3
Number of liter after 150 litres 0,01


Results of the calculation :
Cold water Hot water
Coefficient computed 0 0
Minnimum inner diameter of the supplying tube :

Abacus used by the french code :
Coefficient Minimum inner diameterCorresponding tubing (CTS)
2 10 mm 3/8 ''
3 12 mm
4 13 mm1/2 ''
7 16 mm5/8 ''
12 19 mm3/4 ''
15 20 mm
This chart is extracted from this graph of the french plumbing code :
Diameter of tubing



Conclusion.

Last messages from the forum


Created : 17 feb 2007  - Update : 27 feb 2007


Partenaires :